Bore-Wrap is a simple application and can be completed with as few as 3 people or as many as 10. The time to apply is usually measured in feet per minute. With 3 people doing a girthweld protection, it is about 1.5 feet per minute. With 6 to 10 people performing a...
No. Bore-Wrap® is a sacrificial outerwrap and does not shield CP. Its purpose is to protect the underlying corrosion coating so that CP can function properly after installation.
Unlike liquid coatings, Bore-Wrap® is a composite laminate that resists shear, gouge, and impact forces. Epoxies may resist abrasion but are often brittle under HDD stresses, while Bore-Wrap flexes and absorbs energy. Bore-Wrap is an additional mechanical...